Nqa entry test failed
http://labnario.com/huawei-network-quality-analyzer-nqa/ WebNote that you are not recommended to perform a UDP-jitter test on ports from 1 to 1023 (known ports). Otherwise, the NQA test will fail or the corresponding services of this port …
Nqa entry test failed
Did you know?
WebBefore the NQA test group starts, the initial state of the reaction entry is invalid. If probe failure occurs consecutively for 10 times or more since the test group starts, the state of … Web19 okt. 2024 · I have 5 felids: tolerance, ref stand, UUT, Error, =IF (ABS (D3-H3)<=B3,"Pass","Fail") I would like to be able to input #'s into the cells and get pass and …
WebIf you do not specify an NQA operation, the command displays the current monitoring results of reaction entries for all NQA operations. item-number: Specifies a reaction entry by its ID in the range of 1 to 10. If you do not specify a reaction entry, the command displays the results of all reaction entries. Usage guidelines Web10 aug. 2024 · 1、nqa基本概念 1.测试组 nqa测试组是一组测试参数的集合,如测试类型、测试目的地址、测试目的端口等。nqa测试组由一个管理员名称和一个操作标签来标识。管理员通过nqa测试组来实现对nqa测试的管理和调度。在一台设备上可以创建多个nqa测试组,可以同时启动多个nqa测试组进行测试。
Web[SwitchA-nqa-admin-test-icmp-echo] reaction 1 checked-element probe-fail threshold-type consecutive 5 action-type trigger-only [SwitchA-nqa-admin-test-icmp-echo] quit # Start the NQA operation. [SwitchA] nqa schedule admin test start-time now lifetime forever # Configure track entry 1, and associate it with reaction entry 1 of the NQA operation. WebIn most NQA tests, you only need to configure the NQA client; while in TCP, UDP-echo and UDP-jitter tests, you must configure the NQA server. You can create multiple TCP or …
Web4 nov. 2024 · %Nov 4 02:00:11:074 2024 OA-H3CS7506X-IRF NQA/6/NQA_ENTRY_PROBE_RESULT: Reaction entry 1 of NQA entry admin-name admin operation-tag test: probe-fail. %Nov 4 02:00:11:075 2024 OA-H3CS7506X-IRF TRACK/6/INFO: The state of track entry 1 changed from Positive to Negative.
Web1 aug. 2024 · H3C 路由器智能选路NQA策略本篇介绍H3C产品的NQA配置,配置NQA联动检测线路是否故障来达到智能切换线路。NQA概念:NQA(Network Quality Analyzer, … bunton reel mowersWebDo not perform a UDP jitter test and a voice test on ports from 1 to 1023 (known ports). Otherwise, the NQA test fails or the corresponding services of this port are unavailable. Examples # Configure the destination port number of a test operation as 9000. system-view [Sysname] nqa entry admin test [Sysname-nqa-admin-test] type udp-echo bunton mower historyWeb自动执行测试的时间间隔frequency必须大于发送探测报文时间间隔interval和一次NQA测试发送探测报文数目probe-count的乘积 NQA与静态路由联动是在NQA测试例检测到链路故 … bunton rdWeb当NQA result为failed时,关联静态路由肯定撤销。路由表中存在的应该为其他路由协议或配置产生的相同路由,在NQA track的路由被撤销后,浮动到路由表。 hallmark christmas dvd movies for saleWeb(1) 按照 图1-1 创建VLAN,在VLAN中加入对应的端口,并配置各VLAN接口的IP地址,具体配置过程略。 (2) 在Switch A上配置NQA测试组 system-view # 创建管理员名为admin、操作标签为test的NQA测试组。 [SwitchA] nqa entry admin test # 配置测试类型为ICMP-echo。 [SwitchA-nqa-admin-test] type icmp-echo # 配置目的地址为10.1.2.2。 … bunton park north alburyWeb23 sep. 2024 · h3c做nqa的相关配置及作用,H3C的nqa作用主要是用来做主备路由使用,保障线路通常。 一、组网需求:Server可以通过两台路由器到达对端线路保证冗余及断线自动切换 二、实际配置nqanqa主要分三个步骤1、配置nqa检测。2、配置track与nqa的关联。3、所写的静态路由关联track 具体配置命令如下:1、需要 ... hallmark christmas dvd collectionWebWhen you configure an NQA ICMP echo operation, follow these restrictions and guidelines: · Make sure the devices can reach each other before you start the NQA operation. · You cannot modify the operation configuration for a running NQA operation. Procedures # Create an NQA ICMP echo operation. system-view [DeviceA] nqa entry admin test hallmark christmas dvd releases